1. Turn MASTER SWITCH to OFF.
2. Remove instrument panel for access (page 11-2).
3. Remove rear main harness circuit 38 plug (1) from
instrument panel cable assembly circuit 38 jack (2).
4. Remove instrument panel cable assembly circuit 27
plug (3) from instrument panel circuit breaker
jack (4).
5. Measure
resistance
between instrument panel cable
assembly circuit 38 jack (2) and circuit 27 plug (3).
6. Does
multimeter
read O ohms?
1. Repair rear main harness circuit 38 (page 14-3).
2. Verify no faults found.
1. Install rear main harness
plug on dome light jack.
2. Repair instrument panel
cable assembly circuit 38
(page 14-3).
3. Verify no faults found.