TM 9-2350-261-20-1
1. Turn MASTER SWITCH to OFF.
2. Install instrument panel light buIbs.
3. Install instrument panel illumination light cover
lenses and gaskets.
4. Remove instrument panel for access (page 11-2).
5. Remove front main harness plug (1) from lighting
control switch jack (2).
6. Remove from main harness circuit 40 plug (3) from
either illumination light jack (4).
7. Measure resistance between front main harness
lighting control switch plug (1) pin B (5) and
illumination light plug circuit 40 (3).
8. Does multimeter read O ohms?
1. Replace main light switch (page 11-9).
2. Verify no faults found.
1. Repair front main harness
circuit 40 (page 14-3).
2. Verify no faults found.
3-108