TM 9-2350-261-20-1
1.
2.
3.
4.
5.
Lower trim vane (see your -10).
Open power plant front access door (see your -10).
Remove right headlight wiring harness plug (1)
from connector jack (2) at carrier bulkhead.
Measure voltage between front main wiring harness
jack (2) pin C (low beam) (3) or pin B (high beam)
(4) and ground.
Does multimeter read less than 17 volts?
1. Turn MASTER SWITCH to OFF.
2. Install right headlight wiring harness circuit 17
(high beam) or 18 (low beam) on service headlight.
3. Repair front main wiring harness circuit 17 or 18
between bulkhead and dimmer switch (page 14-3).
4. Verify no faults found.
1. Repair faulty right head-
light wiring harness
(page 14-3).
2. Verify no faults found.
3-81