Home
Download PDF
Order CD-ROM
Order in Print
N O E X T E R I O R L I G H T S O P E R A TE
B L A C K O U T D R I V E L I G H T D O E S N O T W O R K
TM-9-2350-261-20-1 Carrier Personnel Full Tracked Armored M113A2 2350-01-068-4077 Carrier Command Post Light Tracked M577A2 2350-01-068-4089 Manual
Page Navigation
246
247
248
249
250
251
252
253
254
255
256
TM 9-2350-261-20-1
1. Remove master power harness circuit 10 plug (1)
from instrument panel circuit breaker (2).
2. Measure
resistance
between master power harness
circuit 15 plug (3) and circuit 10 plug (l).
3. Does
multimeter
read 0 ohms?
1. Install master power harness circuit 10 and 15
plugs.
2. Replace lighting control switch (page 11-9).
3. Verify no faults found.
1. Install front main harness
lighting control switch plug
on switch.
2. Repair master power
harness (page 14-3).
3. Verify no faults found.
3-74