Table 2-1. Unit Level Preventive Maintenance Checks and Services for M113A2 FOV
Item
Interval
Item To
Procedure
Not Mission
No.
Be
Capable If:
Inspected
94
Semi-
Fuel Sys-
Check heater fuel pump, fuel lines,
Any fuel leaks.
Annual
tem
and connections. Tighten connections
(M577A2
that leak. Replace connections that
only)
continue to leak.
95
Semi-
Exhaust
NOTE
Annual
System
Your carrier may be equipped
(M577A2
with new
exhaust
pipes which
only)
do not require
muffler
clamps.
Check muffler for signs of
exhaust
Any exhaust leaks.
leaks. Tighten loose clamps.