TM 9-2350-261-10F O R D W A T E R U P T O 4 0 I N C H E S D E E PI N I T I A L S E T U PTools:Socket Wrench Adapter(Item 1, App B)Socket Wrench Handle(Item 21, App B)Personnel Required:DriverReferences:TM 11-7010-256-12&PEquipment Conditions:Engine stopped (page 2-184)Carrier tracks blocked (page 2-221)Power control enclosure turned off(M1068 Only)(TM 11-7010-256-12&P)WARNINGW h e n w a t e r d e p thisu n k n o w n o rd e e p e r t h a n 40inches, do not at-t e m p t t ofordstream.Carriermay sink and personnel coulddrown. See task: PREPARA-TION BEFORE WATER OPERA-TION, page 2-275.N O TEThe following fording proce-dures apply to the M113A2,M1068, M577A2, M106A2, M1064,and M1059 carriers.WARNINGP e r s o n n e l c o u l dbe killed or in-j u r e d i f c a r r i e rmoves with some-oneunderit.M a k e s u r e e n g i n eis stopped, parking brake set,and carrier tracks blockedbefore crawling under carrier.1. Check that access covers, draincovers, and final drive drainplugs are in place, straight, andtight. Use socket wrench handleand adapter to check orfinal drive drain plugs.installI2-284Change 3