TM 9-2350-247-34
REPLACE RESTRICTION THERMOSTAT Continued
0067 00
3.
Install blower assembly (7) on coolant heater (3) and turn clockwise. Secure with four nuts (8).
4.
Connect blower assembly lead (9) to terminal number 6 of terminal strap (10).
5.
Place combustion tube assembly (11) on coolant heater (3) and blower assembly (7). Secure with nut (12).
6.
Install guard (13) on coolant heater (3). Secure with four screws (14).
FOLLOW-THROUGH STEPS
1.
Install engine coolant heater in carrier (see your -20).
END OF TASK
0067 00-3/4 blank