TM 9-2350-247-34REPAIR POWER PLANT SLING (M548A3) — Continued 0051 00REPLACE DATA PLATE1. Remove four drive screws (3) from data plate (4). Remove data plate. Discard plate and screws.NOTETo order a new data plate, provide Depot with the same information contained on the originaldata plate: Contract Number, Serial Number, Date of Manufacture, Maximum Work Load,Proof Load, National Stock Number, Part Number, and Commercial and Government EntityCode.2. Locate new data plate (4) in same location. Use the data plate as a template to drill four mounting holes 3/64 to 1/16 inch(1.2 to 1.6 mm) diameter and 5/32 inch (4.0 mm) deep minimum.3. Install four new drive screws (3) on data plate (4).0051 00-4