TM 9-2350-247-34
REPAIR AIR SEPARATOR TANK Continued
0011 00
WARNING
Air pressure in excess of 30 psi (207 kPa) can injure personnel. Do not direct pressurized air at
yourself or others. Always wear goggles.
WARNING
Steam can splash back and burn you. Direct steam splash back away from you and others.
Always wear full eye protection.
CAUTION
Do not expose sealed areas to steam for more than 15 minutes, as existing seal will begin to
deteriorate.
2.
Steam clean inside of separator tank (1). Use clean rags and 30 psi (207 kPa) compressed air to dry.
0011 00-2