REPLACE TACHOMETER CABLE (M548A1) Continued - TM-9-2350-247-20-3_632
REPLACE TACHOMETER CABLE (M548A3)
TM-9-2350-247-20-3 Carrier Cargo Tracked 6 Ton M548A12350010969356 (EIC: AEU) M548A3 2350013696081 (EIC: AE9) Manual
Page Navigation
534
535
536
537
538
539
540
541
542
543
544
TM 9-2350-247-20-3
REPLACE TACHOMETER CABLE (M548A1) — Continued
0522 00
INSTALLATION
1.
Coat tachometer cable (1) with grease (WP 0128 00).
2.
Install
tachometer
cable (1) in tachometer cable housing (2) at instrument panel (3) end. Install gasket (4), if replaced, in
cable housing.
3.
Install slotted washer (5) and washer (6) on
tachometer
cable (1) at tachometer drive adapter (7) end of tachometer cable.
4.
Connect tachometer cable housing (2) to tachometer (8) on instrument panel (3).
NOTE
After completing this step, if material handling kit is installed, install bulkhead protector
(WP 0487 00).
5.
Connect tachometer cable housing (2) to tachometer drive adapter (7).
FOLLOW-THROUGH STEPS
1.
Install power plant rear access door (see your -10).
2.
Install instrument panel (WP 0256 00).
END OF TASK
0522 00-3/4 blank