TM 9-2350-247-20-3
REPLACE TACHOMETER CABLE HOUSING AND ADAPTER (M548A3) Continued
0521 00
2.
Insert tachometer cable (4) under drivers floor plate in carrier. Route through battery compartment bulkhead (5) and into
power plant compartment.
3.
Place new grommet (6) on tachometer cable (4) at battery compartment bulkhead (5).
4.
Place tachometer cable (4) on four weld nuts (7). Secure with four clamps (8), new lock washers (9) and screws (10).
5.
Connect tachometer cable (4) to tachometer drive adapter (1) and tachometer (11).
FOLLOW-THROUGH STEPS
1.
Install drivers side batteries on left side (WP 0293 00).
2.
Connect both battery negative leads (WP 0292 00).
3.
Install drivers floor plate on left side (WP 0395 00).
4.
Lower center seat (see your -10).
5.
Install instrument panel (WP 0256 00).
END OF TASK
0521 00-3/4 blank