REPLACE SPEEDOMETER - TM-9-2350-247-20-3_609
REPLACE SPEEDOMETER CABLE HOUSING AND ADAPTER
TM-9-2350-247-20-3 Carrier Cargo Tracked 6 Ton M548A12350010969356 (EIC: AEU) M548A3 2350013696081 (EIC: AE9) Manual
Page Navigation
514
515
516
517
518
519
520
521
522
523
524
TM 9-2350-247-20-3
REPLACE SPEEDOMETER — Continued
0516 00
INSTALLATION
1.
Place speedometer (3) in instrument panel (7). Secure with bracket (6), two washers (5), and nuts (4).
2.
Install new gasket
(2) in speedometer flexible shaft assembly (1). Connect speedometer flexible shaft assembly to
speedometer (3).
FOLLOW-THROUGH STEPS
1.
Install instrument panel (WP 0256 00).
END OF TASK
0516 00-2