TM 9-2350-247-20-2
REMOVE/INSTALL BATTERY NEGATIVE LEAD(S) -- Continued
0292 00
WARNING
M548A3 requires both negative leads disconnected before maintenance. Each side provides
power that may kill or injure personnel if both negative leads are not completely disconnected.
3.
Connect negative lead (5) to battery (6).
4.
Remove strap (7) from loop (8) and lower cab personnel seat (9). Secure seat with strap (7) through loop (10).
END OF TASK