TM 9-2350-247-20-2
REPLACE AIR BOX HEATER IGNITION COIL, AIR PUMP, AND CHECK VALVE (M548A3)
0185 00
-- Continued
INSTALLATION
1.
Install check valve (1) by inserting valve in the same position as removed and pushing the outlet hose (2) and inlet hose
(3) on valve connectors.
2.
Place two leads (4) on two terminals on air pump (5) and secure with two washers (6) and nuts (7).
3.
Connect air hose (8) and adapter (9) to air pump (5).
4.
Install air pump (5) and coil (10) on mounting bracket (11). Secure with clamp (12), washer (13), and screw (14).
5.
Connect ignition cable (15) and connector (16) to coil (10).
FOLLOW-THROUGH STEPS
1.
Install power plant rear access panel (see your -10).
2.
3.
Lower center seat (see your -10).
END OF TASK