TM 9-2350-247-20-1
REMOVE/INSTALL POWER PLANT (M548A3) Continued
0131 00
29. Remove four screws (1), washers (2), and two trunnion caps (3) from hull.
WARNING
Damaged lifting slings can fall with load. Personnel can be injured or killed. Inspect all slings.
Do not use damaged slings.
30. Inspect sling for damage (WP 0443 00).
WARNING
Lifting sling may slip and allow power plant to drop. Personnel may be injured. Be sure sling is
firmly attached and maintains engine support.
CAUTION
Visually monitor power plant clearance at rear bulkhead to avoid damage to components.
31. Attach sling to power plant lifting points, making sure shackle is in hole stamped B.
32. Carefully remove power plant from carrier with hoist and place on blocks.
0131 00-8