TM 9-2350-247-20-1REMOVE/INSTALL POWER PLANT (M548A3) — Continued 0131 0029. Remove four screws (1), washers (2), and two trunnion caps (3) from hull.WARNINGDamaged lifting slings can fall with load. Personnel can be injured or killed. Inspect all slings.Do not use damaged slings.30. Inspect sling for damage (WP 0443 00).WARNINGLifting sling may slip and allow power plant to drop. Personnel may be injured. Be sure sling isfirmly attached and maintains engine support.CAUTIONVisually monitor power plant clearance at rear bulkhead to avoid damage to components.31. Attach sling to power plant lifting points, making sure shackle is in hole stamped B.32. Carefully remove power plant from carrier with hoist and place on blocks.0131 00-8