TM 9-2350-247-20-1PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0128 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:26Semi-AnnualCooling SystemRadiator Hoses,Pump, and pumpDrive BeltsNOTEM548A1 access is through the passengerseat. M548A3 access is through the rearpower plant rear access panel.a. Check radiator and coolant pump for leaks.Check that all hose clamps and mounting screwsare tight. Check cooling pump drive belt for 3/8inch (10 cm) deflection, cracks and looseness.Tighten loose belts by adjusting pulley. Securebelt adjustment by tightening screws.Any hardwareis loose ormissing or hasany Class IIIfluid leaks.WARNINGAir pressure in excess of 30 psi (207 kpa)can injure personnel. Do not directpressurized air at yourself or others.Always wear goggles.Clean outside of radiator with air gun. Check capand seal for damage that allows leakage. Replaceor repair damaged hardware (WP 0215 00 orWP 0216 00).0128 00-35