TM 9-2350-247-20-1PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0128 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:WARNINGLooking directly at infrared headlightsmay burn your eyes. Do not look directlyinto infrared headlights. Use your handsto feel the heat.b. With helper’s assistance, check operation ofservice headlights, infrared headlights, blackoutmarker lights, blackout headlight, and horn.Repair or replace lights or horn that do not work(WP 0275 00), (WP 0276 00), (WP 0277 00),(WP 0280 00, and WP 0289 00).22Semi-AnnualPivot Steera. Remove plugs and check fluid in both mastercylinders (WP 0371 00). Add fluid (FRH) asnecessary to bring it within 1/2 to 3/4 inch(1.27–1.90 cm) from top cylinder.Either mastercylinder isempty orleaking. AnyClass III leaks.0128 00-32