TM 9-2350-247-20-1
EQUIPMENT DESCRIPTION Continued
0002 00
Low heat
4,500 Btu/hr
1.3 kW/hr
Operating temperature range (surrounding) -65
to +100
F
-54
to +38
C
Electrical requirements
Operating voltage range
20-28.5 V
Amperes draw (maximum above)
30
F
-1
C
Start
12.0 amp
Run
3.5 amp
Amperes draw (maximum below)
30
F
-1
C
Start
15.0 amp
Run
3.5 amp
Performance
Fuel
grades DF-2, DFA, JP-5, JP-8
Fuel flow rate
High flow (normal)
0.021-0.031 lb/min
0.010-0.015 kg/min
Low flow (normal)
0.008-0.014 lb/min
0.004-0.007 kg/min
Fuel pressure (at fuel valve inlet)
3-15 psi
21-103 kN/sq cm
Fuel pump output pressure
3-6 psi
21-41 kN/sq cm
Temperature settings
Overheat thermostat (opens)
245
F
118
C
Restriction thermostat
Opens
220
F
104
C
Closes
190
F
88
C
Dimensions and weight
Height
9 /12 in
34 cm
Length
15 5/16 in
38 cm
Width
6 3/4 in
17 cm
Weight
15 lb
7 kg
Operating capacity
Must be capable of operating against 0.75 in H2O
exhaust restriction
19 mm H2O
Coolant pump
Manufacturer
MP Pumps
Model
12245
Part number
10160875
Electrical requirements
Operate voltage range
20-28.5 V
0002 00-13