TM 9-2350-247-20-1
EQUIPMENT DESCRIPTION Continued
0002 00
Current consumption above 30
F (1
C)
Start
15 amp
Run
9.5 amp
Current consumption below 30
F (1
C)
Start
19.5 amp
Run
17 amp
Heat output
High heat
60,000 Btu
63,300 J
Low heat
30,000 Btu
31,650 J
Fuel pressure requirement
3-15 psi
21.0-103.0 kN/sq cm
Overheat switch setting (maximum)
475
F
246
C
Height
24 1/8 in
61 cm
Diameter (nominal)
8 in
20.3 cm
Width (maximum)
13 in
33 cm
Weight
31 lb
14 kg
Fuel pump
Part number
MS5132-2 (96906)
Output pressure
3-6 psi
21.0-41.0 kN/sq cm
Control box
Part number
7748721 (19207)
Part number (optional control box)
10947220 (19207)
Fuel
Usable fuel
Any hydrocarbon fuel at temperature down to
cloud point except DFA down to -65
F
-54
C
Engine Coolant Heater Kit
Characteristics
Metric Equivalents
Manufacturer
Stewart-Warner
Model
939-J24
Part number
11601698
Heat output (surrounding air temperature)
70
F
21
C
Coolant
High heat
15,000 Btu/hr
4.4 kW/hr
Low heat
8,000 Btu/hr
2.3 kW/hr
Exhaust
High heat
8,000 Btu/hr
2.3 kW/hr
0002 00-12