PARTICULATE PRECLEANER MOTOR DOES NOT WORK (M548A3)Continued - TM-9-2350-247-20-1_479
PARTICULATE PRECLEANER MOTOR DOES NOT WORK (M548A3)Continued - TM-9-2350-247-20-1_481
TM-9-2350-247-20-1 Crane (CAB) Components Recovery Vehicle Full Tracked: light Armored M578 (2360-00-439-6242) (EIC:3LA) Manual
Page Navigation
386
387
388
389
390
391
392
393
394
395
396
TM 9-2350-247-20-1
PARTICULATE PRECLEANER MOTOR DOES NOT WORK (M548A3)—Continued
0103 00
2BY
1. Connect NBC wiring harness connector P1 (1) to M3 heater
wiring harness connector (2).
2. Remove circuit 135G lead (3) from
relay
terminal A2 (4).
3. Measure
resistance
between NBC wiring harness connector J1 (5)
and circuit 135G lead (3).
4. Does
multimeter
read 0 ohms?
YES
NO
2BYN
1. Replace NBC wiring harness
(WP 0531 00).
2. Verify no faults found.
0103 00-4