TM 9-2350-247-20-1PARTICULATE PRECLEANER MOTOR DOES NOT WORK (M548A3) 0103 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0541 00, Item 57)Multimeter (WP 0541 00, Item 29)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)T1. Turn NBC AIR FILTER SWITCH (1) OFF (see your -10).2. Turn MASTER SWITCH OFF.3. Remove NBC wiring harness connector J1 (2) from particulateprecleaner (3).4. Turn MASTER SWITCH ON.5. Turn NBC AIR FILTER SWITCH (1) ON (see your -10).6. Measure voltage between wiring harness connector J1 (2) andground.7. Does multimeter read more than 17 volts?YESNOGO TO BY (PAGE 0103 00-3)0103 00-1