TM 9-2350-247-20-1
PARTICULATE PRECLEANER MOTOR DOES NOT WORK (M548A3)
0103 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0541 00, Item 57)
Multimeter (WP 0541 00, Item 29)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
T
1. Turn NBC AIR FILTER SWITCH (1) OFF (see your -10).
2. Turn MASTER SWITCH OFF.
3. Remove NBC wiring harness connector J1 (2) from particulate
precleaner (3).
4. Turn MASTER SWITCH ON.
5. Turn NBC AIR FILTER SWITCH (1) ON (see your -10).
6. Measure voltage between wiring harness connector J1 (2) and
ground.
7. Does multimeter read more than 17 volts?
YES
NO
GO TO BY (PAGE 0103 00-3)
0103 00-1