TM 9-2350-247-20-1TOO MUCH FOREIGN MATTER IN RESERVOIR (M548A1) 0101 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0541 00, Item 57)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Power plant rear access door removed (see your -10)Center seat raised (see your -10)T1. Check for restricted air strainer (1) (WP 0500 00).2. Clean and oil air strainer (1), if contaminated.3. Is air strainer (1) free of damage?YESNOTN1. Replace faulty air strainer(WP 0500 00).2. Verify no faults found.0101 00-1