TM 9-2350-247-20-1
INSTRUMENT PANEL ILLUMINATION LIGHTS MALFUNCTIONContinued
0045 00
2Y
1. Remove malfunctioning bulbs from instrument panel illumination
light indicator assemblies.
2. Measure resistance between bulb center contact (1) and bulb base
(2) of each bulb for continuity.
3. Does multimeter indicate any continuity?
YES
NO
2YN
1. Replace panel light bulbs as required
(WP 0264 00).
2. Verify no faults found.
3Y
1. Turn MASTER SWITCH OFF.
2. Install instrument panel light bulbs.
3. Install instrument panel illumination light cover lenses and
gaskets.
4. Partially remove instrument panel (WP 0256 00).
5. Remove main harness plug (1) from light switch jack (2).
6. Remove main harness circuit 40 plug (3) from either illumination
light jack (4).
7. Measure resistance between main harness light switch plug (1)
pin B (5) and illumination light plug circuit 40 (3).
8. Does multimeter read 0 ohms?
YES
NO
3YN
1. Repair main harness circuit 40
(WP 0294 00).
2. Verify no faults found.
0045 00-2