TM 9-2350-247-20-1SERVICE STOPLIGHT DOES NOT WORK—Continued 0042 004Y1. Partially remove instrument panel (WP 0256 00).2. Disconnect main wiring harness plug (1) from light switchjack (2).3. Measure resistance between light switch jack (2) pins F and A, Fand B, and F and J with light switch in the STOP LIGHT andPANEL BRT positions. Multimeter should read continuity.4. Measure resistance between light switch jack (2) pins F and C, Fand D, F and E, F and H, F and K, F and L, F and M, and F and Nwith light switch in the STOP LIGHT and PANEL BRT positions.Multimeter should read infinity.5. Are readings correct?YESNO4YN1. Replace light switch (WP 0262 00).2. Verify no faults found.5Y1. Connect main wiring harness plug to light switch.2. Install instrument panel (WP 0256 00).3. Verify no faults found.0042 00-3/4 blank