TM 9-2350-247-10
MAINTENANCE OF AIR CLEANER ELEMENT (M548A1) Continued
0063 00
INSTALLATION
CAUTION
Two non-interchangeable air cleaner types are used on M548A1 carriers. Make sure you install
the right element and container. An air cleaner container with stops inside requires a closed end
element.
1.
To install an open end element, just slide it back into the container. It doesnt matter which end goes in first.
2.
To install a closed end element, put it in the container with the closed end down and turn the element until the slot on the
bottom is between the stops in the container.
3.
Hold the container under the air cleaner head and latch the four clamps.
END OF TASK
0063 00-3/4 blank