TM 9-2350-247-10MAINTENANCE OF AIR CLEANER ELEMENT (M548A1) — Continued 0063 00INSTALLATIONCAUTIONTwo non-interchangeable air cleaner types are used on M548A1 carriers. Make sure you installthe right element and container. An air cleaner container with stops inside requires a closed endelement.1. To install an open end element, just slide it back into the container. It doesn’t matter which end goes in first.2. To install a closed end element, put it in the container with the closed end down and turn the element until the slot on thebottom is between the stops in the container.3. Hold the container under the air cleaner head and latch the four clamps.END OF TASK0063 00-3/4 blank