LO 9-2350-261-12
LUBRICATION ORDER
10 JULY 1990
(Supersedes LO 9-2350-261-12, July 1985)
NOTES
WARNING
Clean fittings with dry cleaning solvent
Dry cleaning solvent burns easily, can cause
(PD-680, Type II) prior to lubrication.
skin rash, and can give off harmful vapors. To
avoid injury, keep away from open fire and use
Check /lubricate grease fitting points after
in well-ventilated area. Wear protective clothing
washing or fording.
and rubber gloves.
NOTE
1. UNIVERSAL JOINTS. Every 150 hours, 1500
When grease fitting will not accept GAA, notify
miles, or semiannually, lubricate all universal
unit maintenance.
grease (GAA) (6 places). Each universal joint
spider has two fittings, but only one of each
pair of fittings requires lubrication.