TM 9-2350-287-20-2
17-28. HYDRAULIC CONTROL PANEL ASSEMBLY REPAIR (continued).
[Art Deleted]
47.
[Step Deleted]
c.
CLEANING AND INSPECTION
WARNING
Dry-cleaning solvent P-D-680 is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame
or excessive heat.
CAUTION
To avoid damage to equipment, do not clean rubber or plastic parts with dry-
cleaning solvent.
1.
Clean all metal parts with dry-cleaning solvent and rag.
2.
Inspect all parts for damage. Replace any damaged parts.
d.
ASSEMBLY
NOTE
Apply Teflon pipe sealant to all male pipe threads prior to assembly.
1.
[Step Deleted]
Change 1 17-87
|