TM 9-2350-277-34
REPLACE RESTRICTION THERMOSTAT Continued
0079 00
3.
Install blower assembly (6) on heater (3) and turn clockwise. Secure with four nuts (9).
4.
Connect blower lead (7) to terminal no. 6 of terminal strap (8).
5.
Place combustion tube assembly (5) on coolant heater (3) and blower assembly (6). Secure with nut (4).
6.
Install guard (2) on coolant heater (3). Secure with four screws (1).
FOLLOW-THROUGH STEPS
1.
Install engine coolant heater in carrier (see your -20).
END OF TASK
0079 00-3/4 blank