TM 9-2350-277-34
REPLACE FUEL CONTROL VALVE Continued
0078 00
LEAK TEST
1.
Repeat high heat fuel flow test. Disconnect both solenoid leads from 24 V dc power source.
2.
One or two drops of fuel may form after solenoid leads are disconnected from power source. Further leakage is not
acceptable.
3.
Replace fuel control valve that leaks.
INSTALLATION
1.
Connect fuel control valve lead (13) to terminal strap (14).
2.
Connect two fuel control valve leads (10) and (11) to overheat thermostat (12).
0078 00-5