TM 9-2350-277-20-1
FLUORESCENT LIGHTS DO NOT OPERATE (M1068A3 ONLY)Continued
0102 00
3Y
1. Set power control enclosure AC MAIN switch to OFF (see TM
11-7010-256-12&P).
2. Remove cable W11 plug P2 (1) from light assembly plug P1 (2).
3. Measure resistance between sockets of P2 (1) and pins of plug
P17 (3) on cable W11 (4) as follows:
P2 socket H to P17 pin A
P2 socket N to P17 pin B
P2 socket G to P17 pin C
4. Does multimeter read 0 ohms for each measurement?
YES
NO
3YN
1. Replace cable W11 (WP 0845 00).
2. Verify no faults found.
4Y
1. Replace/repair light set assembly (WP 0825 00 and
TM 10-5410-229-13&P).
0102 00-3/4 blank