TM 9-2350-261-20-1
SUSPENSION LOCKOUT DOES NOT RELEASE (M741A1 ONLY)
INITIAL SETUP
Tools:
General Mechanics Tool Kit
Personnel Required:
Unit Mechanic
References:
See your -10
See your -12
Equipment Conditions:
(Item 30, App D)
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Ramp lowered (see your -10)
Drivers power plant access panel removed
(see your -10)
Power plant rear access panels
(see your -10)
removed
1. Raise and lower ramp (see your -10)
2. Does ramp operate normally?
YES
I
1. Check hydraulic reservoir fluid level (see your -12).
2. Is reservoir level correct?
1. Do any of the lockout cylinders retract?
1. Replace suspension lockout cylinders that do not re-
tract (page 28-72).
2. Verify no faults found.
1. Troubleshoot ramp system:
See task: Ramp operation
is slow or sluggish
(page 3-184), or Ramp will
not raise or free falls
(page 3-185).
2. Verify no faults found.
1. Service hydraulic reservoir
(see your -12).
2. Verify no faults found.
1. Replace suspension lockout
control valve (page 28-56).
2. Verify no faults found.
3-194