TM 9-2350-261-20-1
SUSPENSION LOCKOUT DOES NOT EXTEND (M741A1 ONLY)
INITIAL SETUP
Tools:
General Mechanics Tool Kit (Item 30, App D)
Materials/Parts:
Wiping rag (Item 61, App C)
Personnel Required:
Unit Mechanic
Helper (H)
See your -10
See your -12
Equipment Conditions:
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Ramp lowered (see your -10)
1. Raise and lower ramp (see your -10).
2. Does ramp raise normally?
YES
1. Check hydraulic reservoir fluid level (see your -12).
2. Is reservoir full?
1. Troubleshoot ramp system.
See task: Ramp operation
is slow or sluggish
(page 3-184), or Ramp will
not raise or free falls
(page 3-185).
2. Verify no faults found.
1. Semite hydraulic reservoir
(see your -12).
2. Verify no faults found.
GO TO NEXT PAGE
3 - 1 8 9