TM 9-2350-247-20-3
REPLACE TACHOMETER CABLE (M548A1) Continued
0522 00
3.
Remove slotted washer (5) and washer (6) from tachometer cable (7) at tachometer drive adapter (2) end.
4.
Pull tachometer cable (7) out of tachometer cable housing (1) at instrument panel (4) end. Check gasket (8) in cable
housing. Replace gasket if necessary.