TM 9-2350-247-20-3
REPLACE TACHOMETER CABLE HOUSING AND ADAPTER (M548A1) Continued
0520 00
4.
Connect tachometer cable housing to tachometer (WP 0519 00).
5.
Secure tachometer cable housing (6) to hull weld nuts (7) with four clamps (8), washers (9), and screws (10).
6.
Install two clips (11) on lower bulkhead panel (12) with four screws (13), washers (14), and new lock nuts (15).
NOTE
After completing this step, if material handling kit is installed, install bulkhead protector
(WP 0487 00).
7.
Push tachometer cable housing (6) firmly into two clips (11).
FOLLOW-THROUGH STEPS
1.
Install power plant rear access covers/door (see your -10).
2.
Install left cab floor plate (WP 0394 00).
3.
Install instrument panel (WP 0256 00).
END OF TASK
0520 00-5/6 blank