TM 9-2350-247-20-2
REPLACE GENERATOR TO REGULATOR WIRING HARNESS (M548A3)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Maintenance Level
References
Unit
See your -10
Tools and Special Tools
General Mechanic's Tool Kit (WP 0541 00, Item 57)
Equipment Condition
Materials/Parts
Engine stopped (see your -10)
Tiedown strap (WP 0542 00, Item 43)
Carrier blocked (see your -10)
Lock nut (3)
Personnel Required
Center seat raised (see your -10)
Unit Mechanic
Power plant rear access panel removed (see your -10)
Helper (H)
REMOVAL
1.
Disconnect wiring harness connector (1) from generator (2).
2.
Disconnect wiring harness connector (3) from regulator (4).
3.
Disconnect wiring harness connector (5) from connector (6) on battery box bulkhead (7).
4.
Cut tiedown strap (8) and remove from wiring harness (9) and other wiring harnesses. Discard tiedown strap.