TM 9-2350-247-20-2
REPLACE SECONDARY FUEL FILTER (M548A1) -- Continued
0177 00
REMOVAL
NOTE
Remove tubes and hoses with clamps attached. Attach clamps to replacement hoses and tubes.
1.
Place container under filter (1). Open drain valve (2) and loosen filter plug (3) to allow fuel to drain.
2.
Disconnect inlet hose (4) and outlet hose (5) from elbow (6) and elbow (7) on cover (8).
3.
Disconnect circuit 1A and 1B plug (9) at connector on generator field switch (10).
4.
Remove two screws (11), washers (12), lock nuts (13), and cover (8) with filter (1) attached. Discard lock nuts.