TM 9-2350-287-34 5-2. COOLING FAN DRIVE ASSEMBLY REPAIR  (continued). c. CLEANING  AND  INSPECTION WARNING 1. 2. 3. 4. 5. 6. Drycleaning  solvent  P-D-680  is  toxic  and  flammable.  Always  wear  protective  goggles and gloves, and use only in a weli-ventilated area. Avoid contact with skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flames or excessive heat. Clean all parts with drycleaning solvent. Inspect inner housing cover (12) for wear, cracks, or distortion. Replace if necessary. Inspect two retainers (14) for burrs, cracks, or chips. Replace  if  necessary. Inspect two sleeves (17) for burrs, cracks, or other damage. Replace is necessary. Inspect two spacers (15) for burrs, sharp edges, cracks, or other damage. Replace if necessary. Inspect two gears (32) for burrs and for cracked, worn, or broken splines. Replace if necessary. 5-5