4-8. AIR CLEANER FAN ASSEMBLY REPAIR (continued).
4.
5.
6.
Disconnect electrical lead (9) from motor
lead (10), and remove sleeve (8) from
electrical lead (9).
Remove screw (5), Iockwasher (6),
capacitor ground lead (11), and motor
ground lead (7) from motor housing (12).
Discard Iockwasher.
Reinstall screw (5) into motor housing
(12) with motor ground lead (7).
7.
Remove motor housing (12) and two preformed packings (18 and 19) from impeller housing (3). Discard
packings.
8.
Remove screw (1), Iockwasher (2), ground lead (1 6), and clip(17) from impeller housing (3). Reinstall screw
(1) and clip(17) in impeller housing (3). Discard Iockwasher.
9.
Remove four screws (23) and Iockwashers (22) and capacitor lead assembly (21) from impeller housing (3).
Discard Iockwashers.
10.
Remove spring pin (20) from impeller housing (3). Discard spring pin.
4-25
|