TM 9-2360-287-34
12-3. APU GEARCASE REPAIR (continued).
Sealant adhesive can burn easily, can give off harmful vapors, and is harmful to skin
and clothing. To avoid injury or death, keep adhesive away from open fire and use in
a weii-ventilated area. if adhesive gets on skin or clothing, wash immediately with
soap and water.
28.
Connect leads 61, 478A, and GND (9, 10, and 11) and cables GND, 66, and 62 (6, 7, and 8) to generator
terminal box (12). Coat generator terminals, cables, and leads with sealant adhesive.
29.
Secure hydraulic fitting (4) to bracket (3) with U-clamp
(5) and two nuts (1) and new Iockwashers (2).
FOLLOW-ON MAINTENANCE:
Install chain cover and fill APU gearcase with oil (para 12-1).
Install APU (refer to TM 9-2350-287-20-2).
Install APU stand (refer to TM 9-2350-287-20-2).
Test APU (refer to TM 9-2815-221-34&P).
12-16
|