Page Title: APU GEARCASE REPAIR (continued)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2350-287-34 12-3.  APU  GEARCASE  REPAIR  (continued). 10. Loosen six nuts (36) and washers (37), then turn and remove generator (15) from housing (27). Remove six nuts (36) and washers (37). Discard nuts. 11. Remove fitting assembly (30) and elbow (33) from hydraulic pump (32). 12. Remove two screws (35) and lockwashers (34) and pump (32) from housing (27). Discard Iockwashers. 13. Remove key (31) from pump (32) shaft. 14. 15. 16. 12-8 Remove four screws (41) and Iockwashers (40) from adapter (39). Discard Iockwashers. Install two 3/8-16 screws in holes in adapter (39), and alternately tighten screws until adapter (39) is removed from housing (27). NOTE Perform step 16 only if studs are damaged. Remove any damaged studs (38) from housing (27).