114. HYDRAULIC ACTUATOR REPAIR (continued).
12.
Install four nuts (4) and new Iockwashers (5) on four tie rods (2) at end cap (1).
13.
Install four nuts (4) and Iockwashers (5) on four tie rods (2) at gland (3).
14.
Torque eight nuts (4) evenly in cross-pattern style as follows:
l Tighten nut A to 5 ft-lb (7 N·m) on first Cycle.
• Tighten nut B to 20 ft-lb (27 N·m) on second cycle.
• Tighten nut C to 40 ft-lb (54 N·m) on third cycle.
• Tighten nut D to 65 ft-lb (86 N·m) on fourth cycle.
15.
Coat nonpainted areas of actuator (6) with corrosion preventive.
16.
Install two protective caps (22) in gland (3) and end cap (1).
FOLLOW-ON MAINTENANCE:
• Install hydraulic actuator (refer to TM 9-2350-287-20-2).