TM 9-2350-287-20-2
– KEY –
Expected Temperatures
Lubricants
Capacities
Intervals
Above 15°F
+40°F to -10°F
+40°F to -65°F
(Above -9°C)
(+4°C to -26°C) (+4°C to -54°C)
OE/HDO
Intervals are
(MIL-L-2104D)
as follows:
LUBRICATING OIL,
D-Day; Daily
Internal Combustion
Intervals are
Engine, Tactical
b a s e d o n
Service
normal hours
of operation
APU Chaincase
1 qt
OE/HDO
and moder-
(0.9 L)
15W40
ate operating
conditions.
NOTES:
10. APU CHAINCASE DRAIN.
WARNING
APU engine oil is hot after operation. Be careful when working in the APU compartment
after the APU engine has been running. Failure to follow this warning can result in
severe burns.
After APU operation, park vehicle on level ground (refer to TM 9-2350-287-10). Open APU side door (refer to TM 9-
2350-287-10). Position a container under chaincase drain plug (28). Remove drain plug (28) from the APU and clean
with drycleaning solvent. After oil has drained, apply Teflon antiseize tape to drain plug (28) and install drain plug (28)
in the APU. Remove filter plug (27) from the APU and add oil through filler plug hole until oil level reaches bottom of
filler plug hole. Clean filler plug (27) with drycleaning solvent and install filler plug (27) in the APU.
G-11
|