TM 9-2350-287-20-2
18-27. APU CABLE ASSEMBLY (11671380-2) REPLACEMENT (continued).
3.
Remove nut (10), two Iockwashers (8), APU diode (9), and lead assembly circuit R (2) from preheat solenoid
(7) side terminal. Discard lockwasher.
4.
Remove cable assembly 11671380-2 from APU.
b.
INSTALLATION
WARNING
1.
2.
Adhesives can burn easily, can give off harmful vapors, and are harmful to skin and clothing. To
avoid injury or death, keep away from open fire and use in a weii-ventilated area. if adhesive gets
on skin or clothing, wash immediately with soap and water.
NOTE
Seal all exposed terminals with sealant adhesive.
Install cable assembly 11671380-2 on APU.
Install two new lockwashers (8) and nut (10) securing lead assembly circuit R (2) and APU diode (9) to preheat
solenoid (7) side terminal.
18-68
|