TM 9-2350-287-20-2
18-23. APU CABLE ASSEMBLY (11672191) REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
Initial Setup:
Tools/Test Equipment:
Equipment Conditions:
. General mechanic’s tool kit (Item 24,
. Vehicle parked on level ground (refer to
Appendix I)
TM 9-2350-287-10).
. MASTER switch set to OFF (refer to
Materials/Parts:
TM 9-2350-287-10).
. Sealant adhesive (Item 6, Appendix D)
. Battery ground cables disconnected (para 7-41).
. Self-locking nut (Item 322, Appendix H)
. APU air intake plenum removed (para 18-17).
a.
REMOVAL
1.
Disconnect cable 11672191 plug CKT66 (1) from starter relay (2).
2.
Remove self-locking nut (5) and washer (4) securing lead 62 of cable 12329640 (6) and lead 66 (3) of cable
11672191 to positive terminal B at generator terminal box (7).
3.
Remove cable 11672191 from APU.
b.
INSTALLATION
WARNING
Adhesives can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. If adhesive gets on skin or clothing, wash immediately with soap and
water.
NOTE
Seal all exposed terminals with sealant adhesive.
1.
Install cable 11672191 on APU.
2.
Install self-locking nut (5) and washer (4) securing lead 62 (6) and lead 66 (3) to positive terminal B at generator
terminal box (7).
3.
Connect cable 11672191 plug CKT66 (1) to starter relay (2).
18-60
|