TM 9-2350-287-20-2
18-6. APU OIL DRAIN TUBING AND FITTINGS AND DRAIN VALVE CATCH ASSEMBLY
REPLACEMENT (continued).
d.
1.
2.
3.
4.
5.
6.
7.
8.
9.
WARNING
Sealing compounds can burn easily, can give off harmful vapors, and are harmful to
skin and clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. if sealing compound gets on skin or clothing, wash immediately with
soap and water.
Apply sealing compound to threads and install nipple (23) and tee (21) on APU.
Apply sealing compound to threads and install nipple (20) and elbow (16) on tee (21).
Install tube assembly (15) on elbow (16).
install bracket (6) and clamp (11) on tube assembly (15) with screw (9), new Iockwasher (10), and
Install bracket (6) on APU with two screws (8) and new Iockwashers (7).
Apply sealing compound to threads and install nipple (13) and elbow (14) on tube assembly (15).
Connect hose (5) to elbow (14).
Install clamp (19) on nipple (20) and APU with screw (18) and new Iockwasher (17).
Install bushing (22) and valve (4) on tee (21).
nut (12).
18-16
INSTALLATION
|