17-28. HYDRAULIC CONTROL PANEL ASSEMBLY REPAIR (continued).
33.
Remove two adapters (67 and 69) and packings (66 and 68) from pressure gage assembly (16). Discard
packings.
34.
Remove gage (65) from pressure gage assembly (16).
35.
Remove two screws (72), nuts (70), and lockwashers (71) and flow-control valve (51) from hydraulic control panel
assembly (1). Discard lockwashers.
36.
Remove cap (73) from flow-control valve (51).
37.
Remove two screws (77), nuts (74), lockwashers (75), and washers (76) from pressure gage bracket (34), and
remove pressure gage bracket (34) from hydraulic control panel assembly (1). Discard lockwashers.
38.
Remove elbow (50) from flow-control valve (51).
17-85
|