TM 9-2350-287-20-2
15-94. MOUNTED WATER RATION HEATER (MWRH) BRACKET REPLACEMENT (continued).
b.
INSTALLATION
WARNING
Dry-cleaning solvent P-D-680 is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT use near open flame or excessive heat.
NOTE
Perform steps 1 through 3 only if rubber pads were removed.
1.
Clean MWRH bracket (7) with dry-cleaning solvent to remove any rubber pad adhesive residue. Allow bracket to
air-dry.
WARNING
Adhesives can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. If adhesive gets on skin or clothing, wash immediately with soap
and water.
2.
Apply thin coat of rubber adhesive to areas on MWRH bracket (7) requiring rubber pads (5 and 6). Allow adhesive
to dry until tacky.
3.
Install three rubber pads (5 and 6) on
MWRH bracket (7).
4.
Install strap (9) on MWRH bracket (7).
5.
Install MWRH bracket (7) on two
canister compartment shelf supports
(4) using five screws (8), nuts (1), and
new lockwashers (2) and 10 washers
(3).
FOLLOW-ON MAINTENANCE:
? Install mounted water ration heater (refer to TM 9-2350-287-10).
Change 1 15-248
|