15-85. PROJECTILE RACK REMOVAL AID REPAIR (continued)
3.
4.
5.
b.
1.
2.
3.
4.
Remove screw (15), two washers (10), Iockwasher (9), nut (8), and spacer (13) from two plates (11 and 14).
Discard Iockwasher.
Remove two cotter pins (19) and washers (20) from shaft (21), and separate two plates (11 and 14). Discard
cotter pins.
Remove four nuts (16) and Iockwashers (1 7), eight washers (1 8), and four cam followers (22) from two plates
(11 and 14). Discard Iockwashers.
CLEANING AND INSPECTION
Inspect for cracks, bends, or damage. Replace defective parts.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
Clean and inspect four cam followers (22) with drycleaning solvent and rag.
Inspect two nylon wear strips (12) for cracks, tears, and gouges. If damaged, remove from plate(11 or 14).
Clean adhesive residue from plate (11 or 14) with drycleaning solvent. Allow parts to dry.
15-212
|