TM 9-2350-287-20-2
15-46. COMMANDER’S CUPOLA BODY REPAIR (continued).
7.
8.
9.
10.
11.
12.
13.
14.
Adhesive causes immediate bonding on contact with eyes, skin, or clothing and also
gives off harmful vapors. To avoid injury or death wear protective goggles, keep away
from open fire, and use in a well-ventilated area. If adhesive gets in your eyes, try to
keep them open, flush them with water for 15 minutes, and get medical attention.
Apply adhesive to new gasket (27),
and install gasket (27) in body (17).
Install two periscope hooks (37),
washers (40), and springs (39) in
body (17).
Install two new cotter pins (38) on
two periscope hooks (37).
Install latch (30), washer (32),
spacer (33), pin (34), spring (36),
and two new cotter pins (31) on
bracket (35).
Install two bolts (28) and locking
latch assembly (29) on body (17).
Install locking cam (19), cam key
(20), shim(s) (22), and new spring
tension washer (21) on body (17).
Install castle nut (24), shim(s) (25),
latch handle (23), and shim(s) (26)
on body (17).
Install new cotter pin (18) on locking
cam (19).
15-115
|