TM 9-2350-287-20-2
15-46. COMMANDER'S CUPOLA BODY REPAIR (continued).
.
15.
Remove pin (42) and release lever (43) from latch handle (23).
16.
Unscrew and remove pin (41) from latch handle (23).
17.
Remove pin (44), retainer (45), spring (46), and guide (47) from latch handle (23),
18.
Remove hatch door seal (48) from seal channel in door frame. Discard hatch door seal,
b.
CLEANING AND INSPECTION
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flames or excessive heat.
1.
Using drycleaning solvent, clean gasket seat in cupola body and seal channel.
2 .
Inspect all parts for damage or wear. Replace if necessary.
15-113
|